ENVIRONMENTAL
Climatic category 55/125/56
Vibration severity (General) 10Hz, 2000Hz; 0.75mm/98m/s² (10gn) duration 6h
Vibration severity (Additional) 13.3Hz to 2000Hz random with superimposed sinusoids, duration 15 min each of 4 planes. No intermittancies measured when using an H.S.L.I. (High Speed Logic Interrupt) detector with a trip threshold of 2ns
Bump severity 390m/s² (40gn) 4000± 10 bumps
Shock severity 981 m/s² (100gn), for 6ms
Acceleration severity 490m/s² (50gn)

MATERIALS
Insulator Diallyl-phthalate (DAP)
Contact Copper alloy plated hard acid gold
Guides Stainless steel
MECHANICAL
Mechanical operations 500
Insertion & withdrawal force 0.81N max., 0.14N min.
Contact retention 20N min.
ELECTRICAL
Current l.f. at 25°C Tamb. 3A
High Power At 25°C Tamb. 25A
Working Voltage 250V d.c.
Proof Voltage 1000V d.c.

MOULD SIZES

A wide choice of mould sizes are available:

l.f. - 17, 29, 33, 41, 53, 65, 72, 84, and 96.

mixed layout - 5+3, 5+6, 0+7, 17+3, 17+6, 29+3, 29+6, 41+3, 41+6, 53+3


TERMINATION STYLES (low frequency)

Available for both male and female covering p.c.b.s of 1.6, 2.4 and 3.2mm thickness there is a choice of straight and 90°p.c., solder for wire, crimp (22-26 AWG) and wire wrapping. High power contacts are available with solder bucket, straight and 90°p.c.


TERMINATION STYLES (high frequency)

Available for both male and female, they are suitable for twisted pairs, straight and 90° flexible coaxial cable (RG178), straight and 90° semi rigid cable (RG405-UT85) and straight and 90°p.c. Preserved impedance is maintained with flexible and semi rigid coaxial types (50ohm) with a reflection coefficient of 0.13 max. up to 2GHz.


ACCESSORIES

Covers suitable for round or flat cable with side or top entry are available for sizes from 17 up to 65 way (or their equivalent mixed layout).

Where male 90° p.c. connectors are mounted to "daughter boards" a pin shroud can be fitted to all mould sizes to reduce the risk of accidental pin damage.

A full range of tools for crimping and contact removal are available.


GUIDES

A comprehensive range of guides is provided. These may be polarized to provide 36 positions or may be unpolarized. There is a choice of standard, jacketing and ¼ turn locking.